| 1,095 | 106 | 76 |
| 下载次数 | 被引频次 | 阅读次数 |
通过对我国北京、上海、广州等城市既有地铁线路两侧环境振动实测结果及理论分析 ,得到 :我国地铁隧道壁处的垂向Z振级为 75~ 1 1 0dB ;距离隧道中心线 1 0~5 0m范围内 ,振动水平可达到GB1 0 0 70 -1 988《城市区域环境振动标准》中居住区域标准限值的要求 ;同时给出我国地铁既有振动控制措施效果比较 ,其中浮置板道床减振效果最佳 ,其次为轨道减振器 ,各种弹性扣件也有一定减振效果
Abstract:This paper studies the subway's bilateral environment vibration in Beijing,Shanghai and Guangzhou.The research is worked out by site measurements and theoretic analysis methods.It draws the following conclusions:The L vz at tunnel wall is 75~110 dB.Within the extent of 10~50 m from tunnel centre line,the L vz of urban area can be able to meet the standard limitation in GB10070-88《Standard of environment vibration in urban area》.Furthermore,this paper gives the comparative results of vibration controlling in China.The best effect is floating track,the next is track anti-vibrators,various elastic fasteners have anti-vibration result as well.
[1] KurzeUJ .Toolsformeasuringpredictionandreducingtheenvir onmentalimpactfromrailwaynoiseandvibration[J].JournalofSound&Vibration,1996,193(1):237~251.
[2] HoodRA .Thecalculationandassessmentofgroundbornenoiseandperceptiblevibrationfromtrainsintunnels[J].JournalofSound&Vibration,1996,193(1):215~225.
[3] PB82220757,Handbookofnoiseandvibrationcontrolforurbanrapidtransitrailways[R].
[4] KurzwellLG .Ground bornenoiseandvibrationfromundergroundrailsystem[J].JournalofSound&Vibration,1979,66(3):363~370.
基本信息:
DOI:10.16374/j.cnki.issn2095-1671.2003.05.002
中图分类号:TB53
引用信息:
[1]辜小安,任京芳,刘扬,刘宪章,温志伟,陈华,孙家麒,金志春,卢力,王毅,李湘久.我国地铁环境振动现状及控制措施[J].铁道劳动安全卫生与环保,2003(05):206-209.DOI:10.16374/j.cnki.issn2095-1671.2003.05.002.
基金信息: